We don’t want to track every eye movement from the moment we start the experiment. We only want to track the actual trials and not the WELCOME_SCREEN/END_SCREEN.
To select when to record the eye-tracking data, click on the SEQUENCE containing your actual trials. This has a new property in the Properties panel – Record. Checking Record will then only record eye movements made within the SEQUENCE.
This doesn’t automatically set up all the eye tracking functionality. We need to add a set up screen for the camera to be calibrated. It needs to appear outside of the SEQUENCE which now has eye movements being recorded within it. The camera setup needs to be outside the sequence because you first have to set up the tracker before the recording can begin!